Telecom Site Location Specialists
For Expanding Networks
401 North Broad
401 NORTH BROAD
Fact Sheet
| Area per floor: |
118,300 square feet first to fifth floors
97,220 square feet sixth to eleventh floors |
| Land Area: |
118,300 square feet |
| Floor Dimensions: |
528' ´ 225'3" |
| Type construction: |
Reinforced concrete and steel |
| Floor: |
Concrete and steel |
| Ceiling Heights: |
First floor- 13'10" to bottom of girder
(20' available between girders on first floor)
Upper floors- 12' from slab to slab |
| Fire towers: |
Five fire towers, complete with smoke landings |
| Elevators: |
Passenger: 9 CABS ranging from 2,500-4,500
pounds capacity
Freight: 7 Freight elevators- capacity 10,000 pounds each, through loading. Each
freight elevator is 20 feet long by 8 feet wide with 8'6" doors. |
| Heat & Air Conditioning: |
Heat is by low pressure Number Two oil fired boiler
system.
Hot water generator furnishes heat through fin coil radiation in finished areas.
Corta type radiators, steam fed, furnishes heat in unfinished areas.
Air Conditioning: 1500 ton cooling tower located on roof.
750 ton Trane centravac compressor furnished chilled water to fan coil units for lower
floors.
Approximately 800 tons of air conditioning is provided via package (self contained) units
located to serve specific areas. |
| Electric Power: |
Dual 13,000 volt supply feeders by Philadelphia
Electric Company
8,000 KVA of transformer capacity existing in building
Switchgear with service transfer capacity.
Current available as follows:
120 Volt -
single phase - 2 wire for lighting
120-208ghting and power
volt - 3 phase - 4 wire for light and power
480 volt 3 phase - 3
wire for power
120-240 volt single
phase - 3 wire is available in eastern end of building for li |
| Sprinkler System: |
Gravity feed sprinkler system, with fire pump
connection
Building interior is wet system - Track level is dry system |
| Roof Tanks: |
3 - 35,000 gallon roof tanks supply sprinkler system
1 - 15,000 gallon tank for domestic water
|
| Column Spacing: |
22' column centers running east and west
21' average variable running north and south |
For more information on services provided
by NCI and how it can assist your company,
please contact us:
NODE COM INC.
116 Village Boulevard
Suite 200
Princeton Forrestal Village
Princeton, NJ 08540
Telephone: 609-587-3432
Fax: 609-631-0436
Email: info@nodecom.com
Top | Services | Solutions | Telecom Sites | About Node Com | Carrier Hotels | International
Services | Contact Us | Home |